1 colonne isolante
ввод; проходной изоляторDictionnaire polytechnique Français-Russe > colonne isolante
-
2 bushing
- проходной изолятор
- переводной ниппель
- высоковольтный ввод
- втулка
- вкладыш (втулка)
- ввод (проходной изолятор)
- ввод (в релейной защите)
- ввод
ввод
Проходной изолятор, имеющий внутреннюю изоляцию из жидкого, твердого, газообразного диэлектрического материала или их комбинации.
[ ГОСТ 27744-88 ]EN
bushing
device that enables one or several conductors to pass through a partition such as a wall or a tank, and insulate the conductors from it.
NOTE 1 – The means of attachment (flange or fixing device) to the partition forms part of the bushing. The conductor may form an integral part of the bushing or be drawn into the central tube of the bushing.
NOTE 2 – The bushings may be of the following types:
- liquid-filled bushing;
- liquid-insulated bushing;
- gas-filled bushing;
- gas-insulated bushing;
- oil-impregnated paper bushing;
- resin-bonded paper bushing;
- resin-impregnated paper bushing;
- ceramic, glass or analogous inorganic material bushing;
- cast or moulded resin-insulated bushing;
- combined insulation bushing;
- compound-filled bushing;
- gas-impregnated bushing.
[IEV number 471-02-01]FR
traversée
dispositif servant à faire passer un ou plusieurs conducteurs à travers une paroi, telle qu’un mur ou une cuve, en isolant le(s) conducteur(s) de cette paroi.
NOTE 1 – Les moyens de fixation (bride ou autre dispositif) sur la paroi font partie de la traversée. Le conducteur peut être solidaire de la traversée ou démontable.
NOTE 2 – Les différentes traversées peuvent être les suivantes:
- traversée à remplissage d’un liquide;
- traversée à isolation liquide;
- traversée à remplissage de gaz;
- traversée à isolation gazeuse;
- traversée en papier imprégné d’huile;
- traversée en papier enduit de résine;
- traversée en papier imprégné de résine;
- traversée en matière céramique, en verre ou en matière inorganique analogue;
- traversée à isolation en résine coulée ou moulée;
- traversée à isolation combinée;
- traversée à remplissage de mélange;
- traversée imprégnée de gaz.
[IEV number 471-02-01]Тематики
EN
DE
- Durchführung, f
FR
вкладыш (втулка)
—
[ http://slovarionline.ru/anglo_russkiy_slovar_neftegazovoy_promyishlennosti/]Тематики
EN
втулка
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]
втулка
Механическая деталь, обычно жесткая трубка, используемая для законцовки зачищенного конца провода.
[ ГОСТ Р МЭК 60598-1-2011]Тематики
- электротехника, основные понятия
EN
высоковольтный ввод
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
переводной ниппель
трубный переводной фитинг
переходник
—
[ http://slovarionline.ru/anglo_russkiy_slovar_neftegazovoy_promyishlennosti/]Тематики
Синонимы
EN
проходной изолятор
Изолятор, предназначенный для провода токоведущих элементов через стенку, имеющую другой электрический потенциал.
[ ГОСТ 27744-88]
проходной изолятор
-
[IEV number 151-15-40]EN
(insulating) bushing
insulator forming a passage for a conductor through a non-insulating partition
[IEV number 151-15-40]
bushing
A bushing is a cyclindrical insulating component, usually made of ceramic, that houses a conductor. It enables a conductor to pass through a grounded enclosure, such as a transformer tank (the physical shell of a transformer), a wall or other physical barrier, to connect electrical installations. In the case of a transformer, bushings protect the conductors that connect a transformer’s core to the power system it serves through channels in the transformer’s housing.
[ABB. Glossary of technical terms. 2010]FR
isolateur de traversée, m
traversée, f
isolateur permettant le passage d'un conducteur à travers une paroi non isolante
[IEV number 151-15-40]
Проходной изоляторПараллельные тексты EN-RU
The circuit breaker is connected via bushings to the rest of the switchgear at the flanges provided.
[Siemens]С другими частями распределительного устройства силовой выключатель соединяется через проходные изоляторы, закрепленные в его фланцах.
[Перевод Интент]Тематики
Классификация
>>>Обобщающие термины
EN
DE
FR
- isolateur de traversée, m
- traversée
3.26 проходной изолятор (bushing): Изолирующее устройство, обеспечивающее прохождение одного или нескольких проводников через внутреннюю или наружную стенку оболочки,
Источник: ГОСТ Р МЭК 61241-0-2007: Электрооборудование, применяемое в зонах, опасных по воспламенению горючей пыли. Часть 0. Общие требования оригинал документа
3.2 проходной изолятор (bushing): Изолирующее устройство, обеспечивающее прохождение одного или нескольких проводников через внутреннюю или наружную стенку оболочки.
Источник: ГОСТ Р МЭК 61241-14-2008: Электрооборудование, применяемое в зонах, опасных по воспламенению горючей пыли. Часть 14. Выбор и установка оригинал документа
3.2 проходной изолятор (bushing): Изолирующее устройство, обеспечивающее прохождение одного или нескольких проводников через внутреннюю или наружную стенку оболочки.
3.1.9 ввод (bushing): Структура, содержащая один или более проводников на выводе из оболочки, изолирующая вывод и средства подсоединения (например, воздушные вводы).
Источник: ГОСТ Р 54828-2011: Комплектные распределительные устройства в металлической оболочке с элегазовой изоляцией (КРУЭ) на номинальные напряжения 110 кВ и выше. Общие технические условия оригинал документа
Англо-русский словарь нормативно-технической терминологии > bushing
-
3 traversée
ввод
Проходной изолятор, имеющий внутреннюю изоляцию из жидкого, твердого, газообразного диэлектрического материала или их комбинации.
[ ГОСТ 27744-88 ]EN
bushing
device that enables one or several conductors to pass through a partition such as a wall or a tank, and insulate the conductors from it.
NOTE 1 – The means of attachment (flange or fixing device) to the partition forms part of the bushing. The conductor may form an integral part of the bushing or be drawn into the central tube of the bushing.
NOTE 2 – The bushings may be of the following types:
- liquid-filled bushing;
- liquid-insulated bushing;
- gas-filled bushing;
- gas-insulated bushing;
- oil-impregnated paper bushing;
- resin-bonded paper bushing;
- resin-impregnated paper bushing;
- ceramic, glass or analogous inorganic material bushing;
- cast or moulded resin-insulated bushing;
- combined insulation bushing;
- compound-filled bushing;
- gas-impregnated bushing.
[IEV number 471-02-01]FR
traversée
dispositif servant à faire passer un ou plusieurs conducteurs à travers une paroi, telle qu’un mur ou une cuve, en isolant le(s) conducteur(s) de cette paroi.
NOTE 1 – Les moyens de fixation (bride ou autre dispositif) sur la paroi font partie de la traversée. Le conducteur peut être solidaire de la traversée ou démontable.
NOTE 2 – Les différentes traversées peuvent être les suivantes:
- traversée à remplissage d’un liquide;
- traversée à isolation liquide;
- traversée à remplissage de gaz;
- traversée à isolation gazeuse;
- traversée en papier imprégné d’huile;
- traversée en papier enduit de résine;
- traversée en papier imprégné de résine;
- traversée en matière céramique, en verre ou en matière inorganique analogue;
- traversée à isolation en résine coulée ou moulée;
- traversée à isolation combinée;
- traversée à remplissage de mélange;
- traversée imprégnée de gaz.
[IEV number 471-02-01]Тематики
EN
DE
- Durchführung, f
FR
проходной изолятор
Изолятор, предназначенный для провода токоведущих элементов через стенку, имеющую другой электрический потенциал.
[ ГОСТ 27744-88]
проходной изолятор
-
[IEV number 151-15-40]EN
(insulating) bushing
insulator forming a passage for a conductor through a non-insulating partition
[IEV number 151-15-40]
bushing
A bushing is a cyclindrical insulating component, usually made of ceramic, that houses a conductor. It enables a conductor to pass through a grounded enclosure, such as a transformer tank (the physical shell of a transformer), a wall or other physical barrier, to connect electrical installations. In the case of a transformer, bushings protect the conductors that connect a transformer’s core to the power system it serves through channels in the transformer’s housing.
[ABB. Glossary of technical terms. 2010]FR
isolateur de traversée, m
traversée, f
isolateur permettant le passage d'un conducteur à travers une paroi non isolante
[IEV number 151-15-40]
Проходной изоляторПараллельные тексты EN-RU
The circuit breaker is connected via bushings to the rest of the switchgear at the flanges provided.
[Siemens]С другими частями распределительного устройства силовой выключатель соединяется через проходные изоляторы, закрепленные в его фланцах.
[Перевод Интент]Тематики
Классификация
>>>Обобщающие термины
EN
DE
FR
- isolateur de traversée, m
- traversée
Франко-русский словарь нормативно-технической терминологии > traversée
-
4 Durchführung, f
ввод
Проходной изолятор, имеющий внутреннюю изоляцию из жидкого, твердого, газообразного диэлектрического материала или их комбинации.
[ ГОСТ 27744-88 ]EN
bushing
device that enables one or several conductors to pass through a partition such as a wall or a tank, and insulate the conductors from it.
NOTE 1 – The means of attachment (flange or fixing device) to the partition forms part of the bushing. The conductor may form an integral part of the bushing or be drawn into the central tube of the bushing.
NOTE 2 – The bushings may be of the following types:
- liquid-filled bushing;
- liquid-insulated bushing;
- gas-filled bushing;
- gas-insulated bushing;
- oil-impregnated paper bushing;
- resin-bonded paper bushing;
- resin-impregnated paper bushing;
- ceramic, glass or analogous inorganic material bushing;
- cast or moulded resin-insulated bushing;
- combined insulation bushing;
- compound-filled bushing;
- gas-impregnated bushing.
[IEV number 471-02-01]FR
traversée
dispositif servant à faire passer un ou plusieurs conducteurs à travers une paroi, telle qu’un mur ou une cuve, en isolant le(s) conducteur(s) de cette paroi.
NOTE 1 – Les moyens de fixation (bride ou autre dispositif) sur la paroi font partie de la traversée. Le conducteur peut être solidaire de la traversée ou démontable.
NOTE 2 – Les différentes traversées peuvent être les suivantes:
- traversée à remplissage d’un liquide;
- traversée à isolation liquide;
- traversée à remplissage de gaz;
- traversée à isolation gazeuse;
- traversée en papier imprégné d’huile;
- traversée en papier enduit de résine;
- traversée en papier imprégné de résine;
- traversée en matière céramique, en verre ou en matière inorganique analogue;
- traversée à isolation en résine coulée ou moulée;
- traversée à isolation combinée;
- traversée à remplissage de mélange;
- traversée imprégnée de gaz.
[IEV number 471-02-01]Тематики
EN
DE
- Durchführung, f
FR
Немецко-русский словарь нормативно-технической терминологии > Durchführung, f
-
5 transformateur immergé dans l'huile
масляный трансформатор
Трансформатор с жидким диэлектриком, в котором основной изолирующей средой и теплоносителем служит трансформаторное масло
[ ГОСТ 16110-82]
масляный трансформатор
Трансформатор, магнитная система и обмотки которого погружены в масло
(МЭС 421-01-14)
[ ГОСТ 30830-2002]EN
oil-immersed type transformer
a transformer of which the magnetic circuit and windings are immersed in oi
[IEV number 421-01-14]FR
transformateur immergé dans l'huile
transformateur dont le circuit magnétique et les enroulements sont immergés dans l'huile
[IEV number 421-01-14]Oil transformers
The magnetic circuit and the windings are immersed in a liquid dielectric that provides insulation and evacuates the heat losses of the transformer.
This liquid expands according to the load and the ambient temperature. PCBs and TCBs are now prohibited and mineral oil is generally used. It is flammable and requires protective measures against the risks of fire, explosion and pollution.
The most commonly used protective measures are the DGPT or the DGPT2: Gas, Pressure and Temperature sensor with 1 or 2 sensing levels on the temperature. This system cuts off the LV load (1st level) then the HV supply (2nd level) when there is a fault inside the transformer. A holding tank is used to recover all the liquid dielectric.
Of the four types of immersed transformer: free breathing transformers, gas cushion transformers, transformers with expansion tank and transformers with integral filling, only the latter are currently installed.
[Legrand]Масляные трансформаторы
Магнитная система и обмотки трансформатора погружены в жидкий диэлектрик, служащий изоляцией и теплоносителем.
Жидкий диэлектрик изменяет свой объем в соответствии с нагрузкой трансформатора и температурой окружающей среды. Поскольку в настоящее время применение полихлорированных дифенилов и тетрахлорбифенилов запрещено, то в основном используют минеральное масло. Оно огнеопасно, поэтому необходимо принимать меры против возникновения пожара, взрыва и загрязнения окружающей среды.
Как правило, применяются системы DGPT (одноуровневые системы, использующие датчики газа, давления и температуры) или DGPT2 – двухуровневые системы. В случае возникновения аномального состояния трансформатора данные системы отключают нагрузку цепей низшего напряжения (первый уровень защиты), а затем питание обмотки высшего напряжения (второй уровень защиты). Активная часть трансформатора находится в баке и полностью покрыта жидким диэлектриком.
Существует четыре типа масляных трансформаторов: трансформаторы с системой свободного дыхания, трансформаторы с газовой подушкой между зеркалом масла и крышкой трансформатора, трансформаторы с расширительным баком и трансформаторы с гофрированным баком. В настоящее время применяют только трансформаторы последнего типа
[Интент]
[http://www.ramo-chelny.ru/konschasti.html]Масляный трансформатор:
- Шихтованный магнитопровод
- Обмотка низшего напряжения
- Обмотка высшего напряжения
- Трубчатый бак
- Термометр
- Переключатель регулировочных отводов обмотки высшего напряжения
- Ввод (проходной изолятор) обмотки низшего напряжения
- Ввод (проходной изолятор) обмотки высшего напряжения
- Расширительный бак
[http://transfcomplect.narod.ru/transformator.html]Тематики
Классификация
>>>EN
DE
FR
Франко-русский словарь нормативно-технической терминологии > transformateur immergé dans l'huile
-
6 Öltransformator
масляный трансформатор
Трансформатор с жидким диэлектриком, в котором основной изолирующей средой и теплоносителем служит трансформаторное масло
[ ГОСТ 16110-82]
масляный трансформатор
Трансформатор, магнитная система и обмотки которого погружены в масло
(МЭС 421-01-14)
[ ГОСТ 30830-2002]EN
oil-immersed type transformer
a transformer of which the magnetic circuit and windings are immersed in oi
[IEV number 421-01-14]FR
transformateur immergé dans l'huile
transformateur dont le circuit magnétique et les enroulements sont immergés dans l'huile
[IEV number 421-01-14]Oil transformers
The magnetic circuit and the windings are immersed in a liquid dielectric that provides insulation and evacuates the heat losses of the transformer.
This liquid expands according to the load and the ambient temperature. PCBs and TCBs are now prohibited and mineral oil is generally used. It is flammable and requires protective measures against the risks of fire, explosion and pollution.
The most commonly used protective measures are the DGPT or the DGPT2: Gas, Pressure and Temperature sensor with 1 or 2 sensing levels on the temperature. This system cuts off the LV load (1st level) then the HV supply (2nd level) when there is a fault inside the transformer. A holding tank is used to recover all the liquid dielectric.
Of the four types of immersed transformer: free breathing transformers, gas cushion transformers, transformers with expansion tank and transformers with integral filling, only the latter are currently installed.
[Legrand]Масляные трансформаторы
Магнитная система и обмотки трансформатора погружены в жидкий диэлектрик, служащий изоляцией и теплоносителем.
Жидкий диэлектрик изменяет свой объем в соответствии с нагрузкой трансформатора и температурой окружающей среды. Поскольку в настоящее время применение полихлорированных дифенилов и тетрахлорбифенилов запрещено, то в основном используют минеральное масло. Оно огнеопасно, поэтому необходимо принимать меры против возникновения пожара, взрыва и загрязнения окружающей среды.
Как правило, применяются системы DGPT (одноуровневые системы, использующие датчики газа, давления и температуры) или DGPT2 – двухуровневые системы. В случае возникновения аномального состояния трансформатора данные системы отключают нагрузку цепей низшего напряжения (первый уровень защиты), а затем питание обмотки высшего напряжения (второй уровень защиты). Активная часть трансформатора находится в баке и полностью покрыта жидким диэлектриком.
Существует четыре типа масляных трансформаторов: трансформаторы с системой свободного дыхания, трансформаторы с газовой подушкой между зеркалом масла и крышкой трансформатора, трансформаторы с расширительным баком и трансформаторы с гофрированным баком. В настоящее время применяют только трансформаторы последнего типа
[Интент]
[http://www.ramo-chelny.ru/konschasti.html]Масляный трансформатор:
- Шихтованный магнитопровод
- Обмотка низшего напряжения
- Обмотка высшего напряжения
- Трубчатый бак
- Термометр
- Переключатель регулировочных отводов обмотки высшего напряжения
- Ввод (проходной изолятор) обмотки низшего напряжения
- Ввод (проходной изолятор) обмотки высшего напряжения
- Расширительный бак
[http://transfcomplect.narod.ru/transformator.html]Тематики
Классификация
>>>EN
DE
FR
Немецко-русский словарь нормативно-технической терминологии > Öltransformator
-
7 oil transformer
масляный трансформатор
Трансформатор с жидким диэлектриком, в котором основной изолирующей средой и теплоносителем служит трансформаторное масло
[ ГОСТ 16110-82]
масляный трансформатор
Трансформатор, магнитная система и обмотки которого погружены в масло
(МЭС 421-01-14)
[ ГОСТ 30830-2002]EN
oil-immersed type transformer
a transformer of which the magnetic circuit and windings are immersed in oi
[IEV number 421-01-14]FR
transformateur immergé dans l'huile
transformateur dont le circuit magnétique et les enroulements sont immergés dans l'huile
[IEV number 421-01-14]Oil transformers
The magnetic circuit and the windings are immersed in a liquid dielectric that provides insulation and evacuates the heat losses of the transformer.
This liquid expands according to the load and the ambient temperature. PCBs and TCBs are now prohibited and mineral oil is generally used. It is flammable and requires protective measures against the risks of fire, explosion and pollution.
The most commonly used protective measures are the DGPT or the DGPT2: Gas, Pressure and Temperature sensor with 1 or 2 sensing levels on the temperature. This system cuts off the LV load (1st level) then the HV supply (2nd level) when there is a fault inside the transformer. A holding tank is used to recover all the liquid dielectric.
Of the four types of immersed transformer: free breathing transformers, gas cushion transformers, transformers with expansion tank and transformers with integral filling, only the latter are currently installed.
[Legrand]Масляные трансформаторы
Магнитная система и обмотки трансформатора погружены в жидкий диэлектрик, служащий изоляцией и теплоносителем.
Жидкий диэлектрик изменяет свой объем в соответствии с нагрузкой трансформатора и температурой окружающей среды. Поскольку в настоящее время применение полихлорированных дифенилов и тетрахлорбифенилов запрещено, то в основном используют минеральное масло. Оно огнеопасно, поэтому необходимо принимать меры против возникновения пожара, взрыва и загрязнения окружающей среды.
Как правило, применяются системы DGPT (одноуровневые системы, использующие датчики газа, давления и температуры) или DGPT2 – двухуровневые системы. В случае возникновения аномального состояния трансформатора данные системы отключают нагрузку цепей низшего напряжения (первый уровень защиты), а затем питание обмотки высшего напряжения (второй уровень защиты). Активная часть трансформатора находится в баке и полностью покрыта жидким диэлектриком.
Существует четыре типа масляных трансформаторов: трансформаторы с системой свободного дыхания, трансформаторы с газовой подушкой между зеркалом масла и крышкой трансформатора, трансформаторы с расширительным баком и трансформаторы с гофрированным баком. В настоящее время применяют только трансформаторы последнего типа
[Интент]
[http://www.ramo-chelny.ru/konschasti.html]Масляный трансформатор:
- Шихтованный магнитопровод
- Обмотка низшего напряжения
- Обмотка высшего напряжения
- Трубчатый бак
- Термометр
- Переключатель регулировочных отводов обмотки высшего напряжения
- Ввод (проходной изолятор) обмотки низшего напряжения
- Ввод (проходной изолятор) обмотки высшего напряжения
- Расширительный бак
[http://transfcomplect.narod.ru/transformator.html]Тематики
Классификация
>>>EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > oil transformer
-
8 oil-cooled transformer
масляный трансформатор
Трансформатор с жидким диэлектриком, в котором основной изолирующей средой и теплоносителем служит трансформаторное масло
[ ГОСТ 16110-82]
масляный трансформатор
Трансформатор, магнитная система и обмотки которого погружены в масло
(МЭС 421-01-14)
[ ГОСТ 30830-2002]EN
oil-immersed type transformer
a transformer of which the magnetic circuit and windings are immersed in oi
[IEV number 421-01-14]FR
transformateur immergé dans l'huile
transformateur dont le circuit magnétique et les enroulements sont immergés dans l'huile
[IEV number 421-01-14]Oil transformers
The magnetic circuit and the windings are immersed in a liquid dielectric that provides insulation and evacuates the heat losses of the transformer.
This liquid expands according to the load and the ambient temperature. PCBs and TCBs are now prohibited and mineral oil is generally used. It is flammable and requires protective measures against the risks of fire, explosion and pollution.
The most commonly used protective measures are the DGPT or the DGPT2: Gas, Pressure and Temperature sensor with 1 or 2 sensing levels on the temperature. This system cuts off the LV load (1st level) then the HV supply (2nd level) when there is a fault inside the transformer. A holding tank is used to recover all the liquid dielectric.
Of the four types of immersed transformer: free breathing transformers, gas cushion transformers, transformers with expansion tank and transformers with integral filling, only the latter are currently installed.
[Legrand]Масляные трансформаторы
Магнитная система и обмотки трансформатора погружены в жидкий диэлектрик, служащий изоляцией и теплоносителем.
Жидкий диэлектрик изменяет свой объем в соответствии с нагрузкой трансформатора и температурой окружающей среды. Поскольку в настоящее время применение полихлорированных дифенилов и тетрахлорбифенилов запрещено, то в основном используют минеральное масло. Оно огнеопасно, поэтому необходимо принимать меры против возникновения пожара, взрыва и загрязнения окружающей среды.
Как правило, применяются системы DGPT (одноуровневые системы, использующие датчики газа, давления и температуры) или DGPT2 – двухуровневые системы. В случае возникновения аномального состояния трансформатора данные системы отключают нагрузку цепей низшего напряжения (первый уровень защиты), а затем питание обмотки высшего напряжения (второй уровень защиты). Активная часть трансформатора находится в баке и полностью покрыта жидким диэлектриком.
Существует четыре типа масляных трансформаторов: трансформаторы с системой свободного дыхания, трансформаторы с газовой подушкой между зеркалом масла и крышкой трансформатора, трансформаторы с расширительным баком и трансформаторы с гофрированным баком. В настоящее время применяют только трансформаторы последнего типа
[Интент]
[http://www.ramo-chelny.ru/konschasti.html]Масляный трансформатор:
- Шихтованный магнитопровод
- Обмотка низшего напряжения
- Обмотка высшего напряжения
- Трубчатый бак
- Термометр
- Переключатель регулировочных отводов обмотки высшего напряжения
- Ввод (проходной изолятор) обмотки низшего напряжения
- Ввод (проходной изолятор) обмотки высшего напряжения
- Расширительный бак
[http://transfcomplect.narod.ru/transformator.html]Тематики
Классификация
>>>EN
DE
FR
трансформатор с масляным охлаждением
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
Англо-русский словарь нормативно-технической терминологии > oil-cooled transformer
-
9 oil-immersed type transformer
масляный трансформатор
Трансформатор с жидким диэлектриком, в котором основной изолирующей средой и теплоносителем служит трансформаторное масло
[ ГОСТ 16110-82]
масляный трансформатор
Трансформатор, магнитная система и обмотки которого погружены в масло
(МЭС 421-01-14)
[ ГОСТ 30830-2002]EN
oil-immersed type transformer
a transformer of which the magnetic circuit and windings are immersed in oi
[IEV number 421-01-14]FR
transformateur immergé dans l'huile
transformateur dont le circuit magnétique et les enroulements sont immergés dans l'huile
[IEV number 421-01-14]Oil transformers
The magnetic circuit and the windings are immersed in a liquid dielectric that provides insulation and evacuates the heat losses of the transformer.
This liquid expands according to the load and the ambient temperature. PCBs and TCBs are now prohibited and mineral oil is generally used. It is flammable and requires protective measures against the risks of fire, explosion and pollution.
The most commonly used protective measures are the DGPT or the DGPT2: Gas, Pressure and Temperature sensor with 1 or 2 sensing levels on the temperature. This system cuts off the LV load (1st level) then the HV supply (2nd level) when there is a fault inside the transformer. A holding tank is used to recover all the liquid dielectric.
Of the four types of immersed transformer: free breathing transformers, gas cushion transformers, transformers with expansion tank and transformers with integral filling, only the latter are currently installed.
[Legrand]Масляные трансформаторы
Магнитная система и обмотки трансформатора погружены в жидкий диэлектрик, служащий изоляцией и теплоносителем.
Жидкий диэлектрик изменяет свой объем в соответствии с нагрузкой трансформатора и температурой окружающей среды. Поскольку в настоящее время применение полихлорированных дифенилов и тетрахлорбифенилов запрещено, то в основном используют минеральное масло. Оно огнеопасно, поэтому необходимо принимать меры против возникновения пожара, взрыва и загрязнения окружающей среды.
Как правило, применяются системы DGPT (одноуровневые системы, использующие датчики газа, давления и температуры) или DGPT2 – двухуровневые системы. В случае возникновения аномального состояния трансформатора данные системы отключают нагрузку цепей низшего напряжения (первый уровень защиты), а затем питание обмотки высшего напряжения (второй уровень защиты). Активная часть трансформатора находится в баке и полностью покрыта жидким диэлектриком.
Существует четыре типа масляных трансформаторов: трансформаторы с системой свободного дыхания, трансформаторы с газовой подушкой между зеркалом масла и крышкой трансформатора, трансформаторы с расширительным баком и трансформаторы с гофрированным баком. В настоящее время применяют только трансформаторы последнего типа
[Интент]
[http://www.ramo-chelny.ru/konschasti.html]Масляный трансформатор:
- Шихтованный магнитопровод
- Обмотка низшего напряжения
- Обмотка высшего напряжения
- Трубчатый бак
- Термометр
- Переключатель регулировочных отводов обмотки высшего напряжения
- Ввод (проходной изолятор) обмотки низшего напряжения
- Ввод (проходной изолятор) обмотки высшего напряжения
- Расширительный бак
[http://transfcomplect.narod.ru/transformator.html]Тематики
Классификация
>>>EN
DE
FR
Англо-русский словарь нормативно-технической терминологии > oil-immersed type transformer
-
10 transformer bushing
трансформаторный ввод
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
Англо-русский словарь нормативно-технической терминологии > transformer bushing
-
11 capacitor bushing
1) Техника: конденсаторный ввод, проходной изолятор конденсатора2) Автоматика: проходной конденсатор -
12 traversée
f1) переход; переезд, переправа2) пересечение (напр. путей)3) рейс; плавание; перелёт; полёт4) пробег; прохождение5) поперечный ход ( при съёмке)6) ввод, проходной изолятор•- traversée de cloisons
- traversée étanche -
13 colonne isolante
сущ.тех. ввод, проходной изолятор -
14 traversée isolée
сущ.тех. ввод, проходной изолятор -
15 Durchführung
(f)вводпроходной изоляторпрохождениевыполнение (напр., программы испытаний) -
16 insulating bushing
изолирующий ввод
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
проходной изолятор
Изолятор, предназначенный для провода токоведущих элементов через стенку, имеющую другой электрический потенциал.
[ ГОСТ 27744-88]
проходной изолятор
-
[IEV number 151-15-40]EN
(insulating) bushing
insulator forming a passage for a conductor through a non-insulating partition
[IEV number 151-15-40]
bushing
A bushing is a cyclindrical insulating component, usually made of ceramic, that houses a conductor. It enables a conductor to pass through a grounded enclosure, such as a transformer tank (the physical shell of a transformer), a wall or other physical barrier, to connect electrical installations. In the case of a transformer, bushings protect the conductors that connect a transformer’s core to the power system it serves through channels in the transformer’s housing.
[ABB. Glossary of technical terms. 2010]FR
isolateur de traversée, m
traversée, f
isolateur permettant le passage d'un conducteur à travers une paroi non isolante
[IEV number 151-15-40]
Проходной изоляторПараллельные тексты EN-RU
The circuit breaker is connected via bushings to the rest of the switchgear at the flanges provided.
[Siemens]С другими частями распределительного устройства силовой выключатель соединяется через проходные изоляторы, закрепленные в его фланцах.
[Перевод Интент]Тематики
Классификация
>>>Обобщающие термины
EN
DE
FR
- isolateur de traversée, m
- traversée
Англо-русский словарь нормативно-технической терминологии > insulating bushing
-
17 bushing
['bʊʃɪŋ]1) Биология: закустаривание2) Авиация: (Goodrich) втулка3) Морской термин: втулка подшипника4) Техника: вводный изолятор, вставлять вкладыш (подшипника), вставлять втулку, высоковольтный ввод, гильза очка питателя, переходник с резьбой, переходной фитинг, переходный фитинг, плетневое заграждение (для регулирования русла), фильера, фильерная пластина, вкладыш (подшипника)5) Сельское хозяйство: использование плетняка (для искусственного заиления канала)6) Химия: вводной изолятор7) Строительство: цилиндрический фитинг (с наружной и внутренней резьбой для соединения труб неодинакового диаметра), футорка8) Железнодорожный термин: переходной изолятор9) Автомобильный термин: вкладыш подшипника, втулка, сайлент-блок, сайлентблок10) Полиграфия: (изолирующая) прокладка11) Электроника: ввод, вывод, изоляционная втулка, проходной изолятор, ввод (изолятор)13) Машиностроение: разбуксовка15) Экология: зарастание кустарником16) Полимеры: наружное кольцо сопла экструдера17) Автоматика: втулка из тефлона, гильза, изолирующая втулка, переходник, вкладыш (подшипника скольжения)18) Пластмассы: направление во втулке, опорная втулка19) Робототехника: изоляционная трубка20) Оружейное производство: пробка21) Общая лексика: вкладыш (коренного подшипника)23) Велосипеды: втулка (стакан), на которую напрессованы внутренние пластины приводной цепи, втулочка, изолятор, муфта, направляющая, подшипник, подшипник скольжения, прокладка24) Высокое напряжение: электрод (в трансформаторе)25) Нефть и газ: вкладыши ротора -
18 wall bushing
2) Электроника: проходной изолятор -
19 Durchführung
сущ.1) общ. осуществление, выполнение, проведение (в жизнь)2) воен. распоряжение3) тех. колодец (устройство пропуска труб в резервуарных понтонах), сквозное отверстие, ввод (Isolator)4) стр. ввод (через стену, потолок)5) юр. производство6) экон. исполнение7) авт. уплотнительная втулка (напр. в месте входа жгута проводов в прибор)8) муз. проведение (темы), разработка (темы)9) электр. проходной изолятор, вывод (напр. обмотки), ввод (напр. через стену, потолок)10) АЭС. ввод (напр. трубопроводов и кабельных линий через стенки защитных оболочек и боксов)11) швейн. направитель13) автом. проводка (через стену, потолок)14) внеш.торг. провоз (транзитом)15) гидравл. вращающийся подвод16) судостр. проход (через палубу, переборку) -
20 Glasdurchführung
сущ.1) тех. проход через стекло2) радио. ввод в стеклянную колбу (в стеклянный баллон), ввод через стекло3) микроэл. стеклянный ввод4) вак. ввод в колбу5) выс. стеклянный проходной изолятор
См. также в других словарях:
ввод (проходной изолятор) — ввод Проходной изолятор, имеющий внутреннюю изоляцию из жидкого, твердого, газообразного диэлектрического материала или их комбинации. [ГОСТ 27744 88 ] EN bushing device that enables one or several conductors to pass through a partition such as a … Справочник технического переводчика
масляный трансформатор — Трансформатор с жидким диэлектриком, в котором основной изолирующей средой и теплоносителем служит трансформаторное масло [ГОСТ 16110 82] масляный трансформатор Трансформатор, магнитная система и обмотки которого погружены в масло (МЭС 421 01 14) … Справочник технического переводчика
ГОСТ 27744-88: Изоляторы. Термины и определения — Терминология ГОСТ 27744 88: Изоляторы. Термины и определения оригинал документа: 3. Арматура изолятора Часть изолятора, предназначенная для механического крепления к электроустановкам или объектам Определения термина из разных документов:… … Словарь-справочник терминов нормативно-технической документации
ГОСТ Р 51330.0-99: Электрооборудование взрывозащищенное. Часть 0. Общие требования — Терминология ГОСТ Р 51330.0 99: Электрооборудование взрывозащищенное. Часть 0. Общие требования оригинал документа: 3.23 Ex компонент: Часть взрывозащищенного электрооборудования, которую отдельно во взрывоопасной среде не используют; при… … Словарь-справочник терминов нормативно-технической документации
ГОСТ Р МЭК 60079-0-2011: Взрывоопасные среды. Часть 0. Оборудование. Общие требования — Терминология ГОСТ Р МЭК 60079 0 2011: Взрывоопасные среды. Часть 0. Оборудование. Общие требования оригинал документа: 3.27 Ex заглушка: Резьбовая заглушка, испытуемая отдельно от оболочки оборудования, но сертифицируемая в его составе и… … Словарь-справочник терминов нормативно-технической документации
ГОСТ Р МЭК 60079-0-2007: Взрывоопасные среды. Часть 0. Оборудование. Общие требования — Терминология ГОСТ Р МЭК 60079 0 2007: Взрывоопасные среды. Часть 0. Оборудование. Общие требования оригинал документа: 3.19 Ex заглушка: Резьбовая заглушка, испытуемая отдельно от оболочки электрооборудования, но сертифицируемая в его составе и… … Словарь-справочник терминов нормативно-технической документации
ГОСТ Р МЭК 61241-0-2007: Электрооборудование, применяемое в зонах, опасных по воспламенению горючей пыли. Часть 0. Общие требования — Терминология ГОСТ Р МЭК 61241 0 2007: Электрооборудование, применяемое в зонах, опасных по воспламенению горючей пыли. Часть 0. Общие требования оригинал документа: 3.41 Ex компонент (Ex component): Часть электрооборудования для потенциально… … Словарь-справочник терминов нормативно-технической документации
ГОСТ Р 51330.1-99: Электрооборудование взрывозащищенное. Часть 1. Взрывозащита вида "взрывонепроницаемая оболочка" — Терминология ГОСТ Р 51330.1 99: Электрооборудование взрывозащищенное. Часть 1. Взрывозащита вида "взрывонепроницаемая оболочка" оригинал документа: 3.6 вал: Деталь круглогопоперечного сечения, применяемая для передачи вращательного… … Словарь-справочник терминов нормативно-технической документации
Трансформатор тока — Измерительный трансформатор тока ТПОЛ 10 … Википедия